WhatsApp
Solution planning

Design the entrance workflow before choosing the terminal.

A reliable proposal connects the credential, device, door or turnstile, network condition, management software and project reporting requirement.

Solution 01

Office Access Control

A company needs reliable employee entry records without slowing down the front door.

Use face for fast flow, fingerprint where identity assurance is more important, and RFID/QR for visitors or fallback.

Face terminalFingerprint terminalRFID/QR readerElectric lock

Reference architecture

1

Face or fingerprint terminal

2

Door relay or access controller

3

Electric lock / exit button

4

LAN or local network

5

TIMY software or customer platform

Final wiring, software and network design depend on the selected model and site conditions.
Solution 02

Factory Time Attendance

A factory needs shift attendance data that remains usable even when network quality is unstable.

Publish shift rules, offline behavior and export format clearly so buyers can evaluate fit before asking for a quote.

Face terminalFingerprint attendance terminalCloud or on-premise software

Reference architecture

1

Attendance terminal

2

Local storage during outage

3

Network sync

4

Attendance software

5

HR/payroll export

Final wiring, software and network design depend on the selected model and site conditions.
Solution 03

Turnstile Face Recognition

A lobby, school or site entrance needs high-throughput identity checks connected to a turnstile gate.

Recognition speed, mounting height, anti-tailgating logic and visitor QR workflow should be specified for each project.

Face terminalQR/RFID readerTurnstile controller

Reference architecture

1

Face terminal

2

Wiegand or relay output

3

Turnstile controller

4

Gate mechanism

5

Access logs

Final wiring, software and network design depend on the selected model and site conditions.
Solution 04

Apartment and Community Access

Residents, visitors and property staff need different credentials and audit trails across many entrances.

Outdoor rating, vandal resistance, network availability and visitor process decide the final device mix.

Waterproof access controlSmart lockQR/RFID reader

Reference architecture

1

Outdoor access terminal

2

Lock or gate control

3

Resident credentials

4

Visitor QR/card

5

Management software

Final wiring, software and network design depend on the selected model and site conditions.
Solution 05

OEM and Platform Integration

A distributor or system integrator needs hardware that connects to its own software and brand workflow.

Do not promise every API on every model; publish a firmware compatibility matrix and request project details.

Face terminalReadersSDK/API packageFirmware support

Reference architecture

1

TIMY device

2

SDK/API or protocol

3

Customer platform

4

Event storage

5

Support and firmware matrix

Final wiring, software and network design depend on the selected model and site conditions.
Solution 06

Elevator Control Face Recognition

A building needs identity verification before users can access authorized floors.

The 2026 catalog states support for max 64 floors with four extension controller boards. Floor permission logic should be confirmed during project design.

Face terminalFingerprint readerElevator control board

Reference architecture

1

Face or fingerprint reader

2

Elevator control board

3

Elevator button panel with LED display

4

Floor permission rules

5

TIMY software / customer platform

Final wiring, software and network design depend on the selected model and site conditions.
Solution 07

OSDP Access Control

A project needs encrypted communication between biometric readers and access controllers.

Catalog shows two working modes: TIMY device as reader connected with OSDP controller, or TIMY device as controller connected with OSDP reader.

OSDP face recognition machineOSDP controllerOSDP reader

Reference architecture

1

TIMY OSDP face recognition machine

2

OSDP controller or OSDP reader

3

Door lock / exit device

4

Access management software

5

Encrypted event flow

Final wiring, software and network design depend on the selected model and site conditions.
Solution 08

BioSecureCard Privacy Solution

Some customers want biometric matching without storing face or fingerprint data on a server.

Catalog states biometric data is stored in the encrypted CPU card, not on a server or external device. This is useful for GDPR-sensitive projects.

BioSecureCardTIMY face / fingerprint terminal

Reference architecture

1

Encrypted CPU card

2

Face/fingerprint biometric template

3

TIMY reader

4

Local card-based matching

5

Access event output

Final wiring, software and network design depend on the selected model and site conditions.
Solution 09

Facial Recognition Smart Locker

A locker operator wants to remove physical keys or cards while keeping user access traceable.

Catalog positions this as a way to reduce lost credentials and replacement cost while improving access security.

Facial recognition access controllerLocker control board

Reference architecture

1

Face recognition controller

2

Locker control board

3

User permission records

4

Access event logs

5

Management software

Final wiring, software and network design depend on the selected model and site conditions.
Solution 010

UHF RFID Parking Access

A parking entrance needs long-distance vehicle identification without stopping every car for close-range card reading.

Catalog lists UHF reader ranges from 5-6 m to 30-40 m and supports multiple tag types for vehicle access management.

TM-SM06 / TM-SM15 / TM-SG220 / TM-SR40UHF tagsBarrier gate interface

Reference architecture

1

UHF tag

2

Long-range UHF reader

3

Gate controller

4

Barrier gate

5

Access record system

Final wiring, software and network design depend on the selected model and site conditions.
Solution 011

Video Intercom + Biometric Access

Apartments or offices need biometric access plus two-way video confirmation and remote unlock.

Catalog states one outdoor terminal can connect to unlimited indoor tablet hosts, with two-way video talk and remote lock control.

Outdoor face/fingerprint terminalIndoor tablet hostElectric lock

Reference architecture

1

Outdoor biometric terminal

2

Indoor tablet host

3

2.4G Wi-Fi network

4

Remote video monitoring

5

Lock open control

Final wiring, software and network design depend on the selected model and site conditions.
Selection comparisons

Choose the biometric method around the operating condition.

These comparisons help define a shortlist; they do not replace model-specific testing or a current datasheet.

Ecoface vs Omniface vs Maxface

Use Ecoface for cost-sensitive projects, Omniface for balanced features, and Maxface for higher-end performance after verifying model specs.

Face vs fingerprint access control

Face is faster and contactless; fingerprint can be lower cost and more controlled, but may be less convenient in wet or dusty environments.

Finger vein vs palm vein

Both support higher-assurance biometric projects. Finger vein is compact; palm vein is more contactless, but model availability and cost matter.

RFID vs QR code access

RFID is stable for employees and residents. QR is strong for visitor and temporary credentials. Many systems use both.

Standalone vs network access control

Standalone is simple for one door. Network systems are better when logs, remote management and multi-site control matter.

Cloud vs on-premise attendance

Cloud helps multi-branch visibility. On-premise can be preferred for stricter data control or limited internet access.

Related hardware

Representative products used across these architectures.

Door count, credential mix, network conditions, software integration and environment determine the final combination.

TM-AIFace11F Dynamic Face & Fingerprint Recognition Terminal
Face + fingerprint terminalOffice doors

TM-AIFace11F

Dynamic Face & Fingerprint Recognition Terminal

A 4.3 inch face and fingerprint recognition terminal for access control and time attendance, listed in the 2026 TIMY catalog with Linux platform, NPU, TCP/IP, USB and Wi-Fi support.

View product
TM-AI07F 5 Inch Face & Fingerprint Access Terminal
Face + fingerprint terminalOffice entrance

TM-AI07F

5 Inch Face & Fingerprint Access Terminal

A 5 inch HD IPS touch screen AI face and fingerprint terminal with aluminium alloy case, 10,000 face capacity and 20,000 fingerprint capacity.

View product
TM-J33Z / TM-J23ZS / TM-S55S TUYA TUYA IP68 Fingerprint & RFID Access Control
Waterproof access controlOutdoor gates

TM-J33Z / TM-J23ZS / TM-S55S TUYA

TUYA IP68 Fingerprint & RFID Access Control

TUYA APP fingerprint and RFID access control devices with IP68 waterproof rating, Wiegand 26/34, remote unlock and temporary password features.

View product
Project evaluation

Build the solution around your site conditions.

Share the door count, user count, credential mix, installation environment and software requirement. TIMY will help narrow the product and integration path.